POSTER |
Paper Id |
Title |
Authors |
5012 |
Implementation of Rural Electrification Scheme - RGGVY, in Uttar Pradesh |
Awadhesh Kumar Sahani |
6006 |
Frequency Control of Interconnected Two-area Restructured Power System along with Wind Power Penetration by DFIG |
Praghnesh Bhatt, S.Ghosal, S.P. Ghoshal, Ranjit Roy |
6007 |
Field Analysis of Transformer Bushing Using FEM Code ANSYS |
R. S. Gorayan , R. K. Srivastava , Rohit Kumar |
6015 |
Power Quality and Energy Efficiency Issues in Compact Fluorescent Lamps – An Indian Perspective |
Narinder Sadana, Gulshan Kumar and Dr. Ashwani Kumar |
6016 |
Performance Evaluation of Asynchronous Generator Based Islanded Wind Energy Conversion System |
Shailendra Sharma and Bhim Singh |
6026 |
Thermal Modeling of Electrical Transformers |
Haritha V V S S, T R Rao, Amit Jain, M Ramamoorty |
6037 |
Effective Single Phase Induction Motor Controller Based On Multi Objective Genetic Algorithm MOGA Using Green Plug Compensator Schemes |
Adel M. Sharaf, Adel A. A. El-Gammal |
6038 |
Efficient Control Strategy for Minimizing Electrical Energy Consumption In Small AC Motorized Loads |
Adel M. Sharaf, Adel A. A. El-Gammal |
6053 |
Adaptive Neural Fuzzy Inference Systems Controller for Hybrid PWM based Vector Controlled Induction Motor Drives |
N.Ravi Sankar Reddy, T.Brahmananda Reddy, J.Amarnath, D.Subbrayudu |
6055 |
Profit maximization with Renewable Energy Sources in Generation Mix |
Yajvender Pal Verma , Ashwani Kumar |
6067 |
Comparative studies of congestion management in deregulated electricity market |
Manasarani Mandala ,C. P. Gupta |
6076 |
An Approach for Formation of Voltage Control Areas based on Voltage Stability Criterion |
Dushyant Juneja, Manish Prasad, and M. K. Verma |
6079 |
Design of PSS for Small Signal Stability Improvement |
Akhila Sri Tharani .P , T.R. Jyothsna |
6081 |
Minimal Loss Configuration for Large-Scale Radial Distribution Systems using Adaptive Genetic Algorithms |
Anil Swarnkar,Nikhil Gupta, K. R. Niazi |
6083 |
Estimation and Elimination of DC Component in Digital Relaying |
K Venkatesh and K S Swarup |
6101 |
Flatness-based Trajectory Generation and Tracking for a DC Motor Drives using MPC |
Chinde Venkatesh,Kanakgiri Krishna,Tiwari Deepak,K Rajesh,S.Ayush |
6112 |
Economic Power Dispatch using Artificial Immune System |
R.Behera, B.B.Pati, B.P.Panigrahi |
6113 |
Particle Swarm Optimization Based Method for Optimal Siting and Sizing of Multiple Distributed Generators |
Naveen Jain, S.N. Singh,S.C. Srivastava |
6116 |
Wavelet and ANN Based Differential Protection of Power Transformer |
Srinivasulu K , D N Vishwakarma , Amrita Sinha |
6128 |
Fuzzy Logic Controlled Unified Power Quality Conditioner for Power Quality Improvement |
Chirag Patel , R. Mahanty |
6150 |
Research Methodolgy for the Life Evaluation of Hollow Polymer Insulators for High Voltage Applications |
S.Farook , Dr. P.Sangameswara Raju |
6154 |
Novel 24-Pulse Rectifier Topology based on Single 3-Phase to Four 3-Phase Transformation using Conventional Transformers for Phase Shifting |
A. N. Arvindan , Anirudh Guha |
6157 |
Loss Adjusted DC Load Flow Method for MW Security Assessment |
J. Pal , A. Barman , A. B. Choudhury |
7007 |
Multi Objective Harmony Search Algorithm For Optimal Power Flow |
S. Sivasubramani , K. S. Swarup |
7019 |
Improvement of Voltage Stability Based on Static and Dynamic Criteria |
M. V. Reddy, V. S. K. Murthy Balijepalli |
7023 |
Experimental Investigations to Identify SFRA Measurement Sensitivity for Detecting Faults in Transformers |
Prameela M., G. Radhakrishna Murthy, Pradeep Nirgude, B. Gunasekaran |
7043 |
Estimation of Fault Location on UHV Transmission Line using Synchronized PMU Measurements |
K Ravishankar, D Thukaram |
7057 |
Comparison of Index Vector & Fuzzy-PSO methods with respect to Optimal Capacitor Placement in Agricultural Distribution System |
K.V.S. Ramachandra Murthy, M. Ramalinga Raju, G. Govinda Rao |
7058 |
An ANN Based Hybrid State Estimator |
Amit Kumar and Saikat Chakrabati |
7067 |
Lightning Impulses Evaluation by Reducing Noise & Smoothing the Data Using FIR Filters |
Vinay Kumar. A , Pradeep Nirgude , B. Gunasekaran |
7070 |
DTC-SVPWM of Induction Motor Drive with Three Level H-Bridges Inverter |
Jagan Mohana Rao Malla, Siva Ganesh Malla |
7080 |
Fuzzy Logic based Fast Critical Clearing Time Assessment |
B.K. Saha Roy,A.K. Pradhan,A.K. Sinha |
7087 |
A Hybrid Method for Fault Location in EHV Multi-Terminal Circuits |
B.R.K.Varma ,P.V. Ramana Rao |
7092 |
Modeling of Sliding Mode Controller-based Synchronous Link Converter as Active Line Conditioner |
Rakesh Babu Bodapati ,Gopala Rao J,Subba Rao Mopidevi |
7093 |
Enhancement of Transient Performance of a Single Machine Infinite Bus System Using Thyristor Controlled Braking Resistor |
B.Yadagiri,A.V.R.S. Sarma |
7099 |
Application of UPQC for Power Quality Improvement |
Yash Pal ,A.Swarup , Bhim Singh |
7122 |
Random Movement of Particle Trajectories in a 3-phase Common Enclosure GIB with and without Coated Electrodes |
Parthasaradhy P ,Dr. Amarnath J,Dr. Prasad P V N |
ORAL |
Session-I DISTRIBUTION SYSTEMS |
6029 |
Comparison of Amorphous & CRGO Core Transformer Losses Under Nonlinear Load Condition |
Vinod Gupta,O Naresh Kumar,Ashok Kumar Kadiyala,U. C. Trivedi,T. P. Govindan |
6032 |
Voltage Stability Enhancement of Radial Distribution System Using Distributed Generators |
Vinodhkumar K,Santhosh Kumar B,Selvan M.P. |
6039 |
A New Technique for Maximum Efficiency and Minimum Electrical Energy Consumption of Single-Phase Induction Motors Based On Particle Swarm Optimization(PSO) |
Adel A A.El-Gammal , Adel M. Sharaf |
6091 |
Wind Speed Forecasting using MRA Based Adaptive Wavelet Neural Network |
Bhaskar Kanna,S.N. Singh |
7055 |
Comparison of Loss Sensitivity Factor & Index Vector methods in Determining Optimal Capacitor Locations in Agricultural Distribution |
K.V. S. Rama Chandra Murthy ,Ramalinga Raju M,Govinda Rao G,Narsimha Rao K |
7062 |
A Resonant Integrator based PLL and AC Current Controller for Single Phase Grid Connected PWM-VSI |
Venkatramanan D,Vinod John |
7128 |
Optimization of Control Parameters in AGC of Microgrid using Gradient Descent Method |
Mallesham G ,Mishra S,Jha AN |
Session-II RENEWABLE ENERGY SOURCES |
6049 |
Reliability Analysis of Power Systems Incorporating Renewable Energy Sources |
Chanan Singh,Arijit Bagchi |
6065 |
Soft Switching Converter Design With PV Array Two Diode Model And Digital Signal Processor Based MPPT For Solar Hybrid Applications |
Senthil Murugan N,Sharmeela C,Saravanan K |
6082 |
Bi-annual Sun Tracking for Solar PV Module Support Structure: Study and Implementation |
Prabodh Bajpai,Vaishalee Dash,N.K. Kishore |
6121 |
Dynamic Analysis of Renewable Energy Systems and their Impact on Smart Grid |
Suhas ,M M Babu Narayanan,S Ashok |
7018 |
Indian Initiatives in Development of Renewable Sources of Energy |
Manohar Govind Raoot,Pushpa Seshadri,S.A Khaparde |
7026 |
VF Controller for Stand Alone Wind Energy Conversion System Employing PMBL Generator |
Sheeja V,Jayaprakash PBhim Singh,Uma R |
7094 |
Steady State assessment of Three Phase Self Excited Induction Generator with Novel Leading VAR Controller and Alleviation of Harmonics with Shunt Active Power F |
Vargil Kumar E,Narsimham P.V.R.L.,Sarma A.V.R.S. |
7116 |
Renewable Energy Certificate Mechanism in India |
SK Soonee,Minaxi Garg,Satya Prakash |
Session-III DEREGULATION & ASSET MANAGEMENT |
6025 |
Congestion Influence on Optimal Bidding in Competitive Electricity Market |
Vijaya Kumar J,Shaik Jameer Pasha,Vinod Kumar D M |
6095 |
Assessment of Marginal and Long-term Surplus Power in Orissa – A Case Study |
ChandraShekhar Reddy Atla,Mallik A. C.,Balaraman K,Dr. Nagaraja Ramappa |
6136 |
Study of HVDC System in Open Access -An Indian System Experience |
Prof. R. K. Pandey,S K Soonee,P Mukherjee,Surajit Banerjee,L Hari |
6146 |
Electric Power Exchanges: A Review |
Yogesh K. Bichpuriya,S. A. Soman |
6148 |
Estimation of CVaR of Unscheduled Interchanges in Availability Based Tariff (ABT) |
Yogesh K. Bichpuriya,Puneet Chitkara |
7085 |
Reliability Evaluation of Radial Feeder Using Two Stage Restoration Strategy |
Vidyasagar Erukulla,P.V.N. Prasad |
7118 |
A Novel Hybrid Method for Short Term Load Forecasting using Fuzzy Logic and New Particle Swarm Optimization(NPSO) |
M Babita Jain,Dr Amit Jain |
Session-IV POWER SYSTEM ANALYSIS |
5009 |
Load Model Impact in Distribution System Reconfiguration Part I: Problem Analysis and Reformulation |
Devender Singh,Rakesh K. Misra |
5010 |
Load Model Impact in Distribution System Reconfiguration Part II: Methodology and Simulation Results |
Devender Singh,Rakesh K. Misra |
6017 |
Power Factor Rebate-Bold Decision from Regulator |
Shefali K. Talati,S. B. Modi,U. C. Trivedi,M.K Dave |
6118 |
Problems Faced by Power System Grid Operators in the Contingency Analysis Studies During the Outage of a Transmission Line |
Tanniru.S.N.R.K,Srinivas |
6130 |
Implementation & Standardization of Medium Voltage Gas Insulated Switchgear from Utility perspective |
P K Jain,P D Gaikwad,S R Mujumdar,V A Sankpal,Deepa Joshi |
7033 |
A Modern Test Environment for the “Smarts†in the Smart Grid |
P.G. McLaren,O. Nayak,J. Langston,M. Steurer,M. Sloderbeck,R. Meeker,P. Forsyth |
7054 |
Topology based approach for Efficient Load flow Solution of Radial Distribution Networks |
K.V.S.Ramachandra Murthy,Ramakinga Raju M,Govinda Rao G,K. Narsimha Rao |
7120 |
Analysis of Power Transformer failure in Transmission utilities |
Shrikant S.Rajurkar,Jayant G.Nandapurkar,Amit R. Kulkarni |
7131 |
Radial Load Bus Voltage Control and Distribution VAR Dispatch |
Siva Sandeep K,Annangi Sriker,Sulte Rod,Sivakumar CH Yesuratnam G |
Session-V POWER QUALITY – I |
6023 |
Mitigation of Various Power Quality Problems Using Unified Series Shunt Compensator in PSCAD/EMTDC |
Asha Kiranmai S,Manjula M,Sarma A.V.R.S. |
6050 |
Wavelet and S-transform Based Multilayer and Modular Neural Networks for Classification of Power Quality Disturbances |
Venkatesh Challa,Siva Sarma D.V.S.S,Sydulu Maheswarapu |
6108 |
Hardware Implementation of Single Phase Dynamic Voltage Restorer |
Dr A Jaya Laxmi,Dr. K. Uma Rao,Dr. M. Sushama,N. Tejasri Devi |
6153 |
THD Mitigation in Line Currents of 6-Pulse Diode Bridge Rectifier Using the Delta-Wye Transformer as a Triplen Harmonic Filter |
Arvindan A N,Abinaya B |
7053 |
Comparison between Conventional, GA and PSO with respect to Optimal Capacitor Placement in Agricultural Distribution System |
K.V.S.Ramachandra Murthy,Ramakinga Raju M,Govinda Rao G |
7078 |
Modeling of Electric Arc Furnace & Control Algorithms for Voltage Flicker Fitigation using DSTATCOM |
Anuradha K,B. P. Muni,A. D. Raj Kumar |
7095 |
A Comparison of Three Topologies of Three-Phase Four-Wire UPQC for Power Quality Improvement |
Yash Pal,Swarup A,Bhim Singh |
Session-VI POWER SYSTEM OPERATION & CONTROL-I |
5016 |
Load Frequency Control in Four Area Power Systems Using Fuzzy Logic PI Controller |
Emre Ozkop S,Ismail H. Altas,Adel M. Sharaf |
6001 |
Adaptive Neuro-Fuzzy FACTS Controller for Transient Stability Enhancement |
Anas Albakkar,O.P. Malik |
6004 |
Damping effects of Supplementary Control Signals for Enhancement of Transient Stability in Multi Machine AC-DC Power Systems |
Uma Vani Marreddy,Ramana Rao P.V. |
6021 |
Experience of Commissioning of PMUs Pilot Project in the Northern Region of India |
V.K. Agarwal,P.K. Agarwal,Rajesh Kumar |
6030 |
Critical Measurement Set with PMU for Hybrid State Estimation |
Jamuna Kamaraj,Swarup K.S |
6063 |
Analysis of Prevention of Induction Motors Stalling by Capacitor Switching |
Mahesh S,Nagendra Rao P S |
6080 |
A Wide Area Synchronized Frequency Measurement System using Network Time Protocol |
Kunal A. Salunkhe,Kulkarni A.M |
6103 |
A Wide-Area Continuous Time Model Predictive Control Scheme for Multi-Machine Power System |
Bibhu Prasad Padhy,S.C. Srivastava,Nishchal K.Verma |
6104 |
A Novel Approach to Small Signal Stability Enhancement using Fuzzy Thyristor Susceptance Control of SVC using Lyapunov Stability |
Harikrishna Durgam,Dhekekar R.S.,Srikanth N.V. |
Session-VII POWER QUALITY - II |
6014 |
Voltage Regulator Placement in Radial Distribution Network using Plant Growth Simulation Algorithm |
Veera Venkata Rama Rao Pokanati,Sivanaga Raju Sirigiri,Venkata Prasad P |
6027 |
Single Phase Active Harmonic Filters for Harmonic Elimination and Power Factor Correction for Distributed Loads |
Vinod Gupta,Kamlesh Keharia,R. B. Kelkar,M. Ramamoorty |
6031 |
Implementation of Single Phase Shunt Active Filter for Low Voltage Distribution System |
Srinath S,Prabakaran S,Mohan K,Selvan M.P. |
6048 |
A Comparative Study of PI and Fuzzy Logic Shunt Active Power Filter in reducing % THD of a Three- Phase Four-wire System |
Suresh Kumar Bhaskaruni,RameshReddy kolli,V. Lalitha |
6126 |
Techniques used for Detection of Power Quality Events- a Comparative Study |
Venkatesh Challa,Siva Sarma D.V.S.S. |
6137 |
A Novel Voltage Stability Index Based On The Polynomial Estimation From Voltage And Current Measurements |
L.V.Prasanna Pogiri,Sarat Kumar Sahu,K.S.R.Anjaneyulu |
6149 |
Design and Simulation of Dynamic Voltage Restorer (DVR) Using Sinusoidal Pulse Width Modulation (SPWM) |
Rajesh Saripalli,Mahesh Kumar Mishra,Sridhar K. |
Session-VIII POWER SYSTEM OPERATION & CONTROL-II |
6114 |
Utilization of GOOSE in MV Substation |
Sushil Joshi |
6120 |
A Distributed Computing Environment for Probabilistic Transient Stability Analysis |
K Jayashree,K. S. Swarup |
6123 |
Distributed Load Flow using Partitioning and Equivalencing of Power Networks |
Angeline Ezhilarasi G, Swarup K S |
7030 |
Fuzzy Neural Network Controller on Load Frequency Control Considering Governor Dead band And Generation Rate Constraints |
Kalyan Chatterjee |
7042 |
State Estimation using LP upper Bound Optimization |
Thukaram D.,Seshadri Sravan Kumar V.,Khincha H.P. |
7124 |
Model-Reference Adaptive Control of Power System Using Surrogate Type Modeling Concepts |
Ramakrishna Gokaraju,Dipendra Rai,Aniruddha Gole |
7129 |
Contingency Analysis For Eastern Regional Grid of INDIA |
Pentayya P,Mukhopadhyay P,Banerjee S,Thakur M K |
7130 |
A simple and efficient approach for Optimal Placement of PMUs-A Case Study for Eastern Regional Grid |
Pentayya P,Mukhopadhyay P,Banerjee S,Thakur M K |
Session-IX HVDC & FACTS |
4005 |
A Comprehensive Survey of Coordinated Control Techniques of FACTS Controllers in Multi-Machine Power System Environments |
B K Singh,N. K. Sharma,A. N. Tiwari |
6008 |
Dynamic Control and Power Quality Improvement of HVDC System Using Three-Level Double Bridge Voltage Source Converter |
D.Madhan Mohan,Bhim S Singh,Bijaya Ketan Panigrahi |
6131 |
Distribution Systems Voltage Profile Improvement with Series FACTS Devices Using Line Flow-Based Equations |
Venkateswararao K,P KAgarwal |
6145 |
STATCOM-SMES SYSTEM Co-ordination in Controlling Power System Dynamics |
Hiren Parmar,Vamsi Krishna K,Dr. Ranjit Roy,Dr. S P Ghoshal |
6156 |
H-Bridge Cascade Multilevel VSC Control for Effective VAR Compensation of Transmission Line |
Ram S.Dhekekar,N.V.Srikanth |
7114 |
Multilevel Modular Converter for VSC-HVDC Transmission Applications: Control and Operational Aspects |
Udana N.Gnanarathna,Aniruddha M.Gole,Sanjay K.Chaudhary |
7123 |
Model Reference Adaptive Control of FACTS |
Dipendra Rai,Ramakrishna Gokaraju,Sherif Faried |
Session-X POWER ELECTRONICS APPLICATIONS – DRIVES |
5014 |
Voltage Controlled PFC Forward Converter Fed PMBLDCM Drive for Air-Conditioner |
Sanjeev Singh,Bhim Singh |
6019 |
Speed Estimation in Five-Phase Syn-Rel Machines using ELO-Algorithm |
M. Rizwan Khan,Atif Iqbal |
6034 |
A Novel GA-Based Self Regulating Tri Loop Self Tuned Modified PID Controller for Hybrid PV-FC-Diesel-Battery Electric Vehicle PMDC Drive System |
Adel A A.El-Gammal,Adel M.Sharaf |
6035 |
A Hybrid PV-FC-Diesel-Battery Electric Vehicle Drive System Based on PSO Self Regulating Multi-Loop Incremental Controller |
Adel A A.El-Gammal,Adel M.Sharaf |
6058 |
Modeling, Design & Control of Disc Rotor Type Stepper Motor |
K. S. Denpiya,A. B. Patel,S H Chetwani,M. K. Shah |
7005 |
Ultra capacitor Based Ride Through System For Control Power Supplies In High Power Converters |
Anand Vivek Ravi,Vinod John |
7038 |
Scilab/Scicos Modeling, Simulation and PC Based Implementation of Closed Loop Speed Control of VSI Fed Induction Motor Drive |
Vijay Babu Koreboina,Shankar J Magajikondi,Raju A B |
7097 |
An Improvement in Dynamic Response of a Direct Torque Controlled Induction Motor Using Sector Advancing Technique |
Narasimham P.V.R.L.Sarma A.V.R.S.,Vargil Kumar E |
Session-XI POWER SYSTEM PLANNING & PROTECTION |
6060 |
Application of Feed Forward Neural Network to Differential Protection of Turbo generator |
Amrita Sinha,D N Vishwakarma |
6090 |
Estimation of Sequence Components using Magnitude Information |
P. S. Nagendra Rao,Sasikiran Vekanuru |
6094 |
Performance Improvement of Digital Distance Relaying Scheme Based on Fuzzy Logic |
Lakshmi Narayana P,U Jayachandra Shenoy,Suresh M |
6111 |
Impact of STATCOM and SSSC Based Compensation on Transmission Line Protection |
Suresh Maturu,U Jayachandra Shenoy |
6138 |
Optimal Allocation of UPFC for Congestion Management using Interior Point Method |
K. Arun Kumar Reddy,S. P. Singh,G. S. Raju |
7044 |
Evaluation of Generation/Network Expansion Requirements to Meet Future Demands |
Thukaram D.,Vyjayanthi C. |
7045 |
Discrimination of Faulted Transmission Lines Using Multi Class Support Vector Machines |
Thukaram D.,Rimjhim Agrawal |
7064 |
Tracing Network flows due to Sources/Sinks using Virtual flow Concept |
Surendra S.,Thukaram D. |
7105 |
An Integrated Model for Transmission Sector using Cooperative Game Theory |
Sudha Balagopalan,Ashok S,Mohandas KP |
Session-XII HIGH VOLTAGE & INSULATION |
5003 |
Grounding System for High Resistivity Limited Area Substations in Hilly Region of Himachal Pradesh |
Ashwani Kumar Sharma,Hans Raj Seedhar |
6010 |
Parametric Analyses on Impulse Voltage Generator and Power Transformer Winding for Virtual High Voltage Laboratory Environment |
Sachin Kumar,N K Kishore,B Hemalatha |
6028 |
An Attempt to Identify Temperature Dependent Non-Linear Insulation Characteristics from Dielectric Response Measurements |
Sandip K.Ojha,Prithwiraj Purkait,Biswendu Chatterjee,Debangshu Dey,Sivaji Chakravorti |
6056 |
Study Of The Transient Overvoltage Profiles In The Power Distribution Network Of Durgapur Steel Plant (DSP) |
Poulomi Mitra,De A.,Chakrabarti A |
6077 |
Design of High Voltage Pulse Transformer for Solid State Pulse Generator for PIII Applications and Prototype Development |
Lakshmi Prasanna P,H. A. Mangalavedekar,Abhijith Tillu,Kavitha Dixit,D. P. Chakravarthy,K. C. Mittal |
6092 |
Surge Transfer Study for Power Transformer using EMTDC/PSCAD |
Veerabrahmam Bathini,Chandra Shekhar Reddy Atla,Balaraman K,Parthasarathi K |
7014 |
An Analytical Study on the Effect of Multiple Dielectrics in the Design of Insulation Systems |
Pradeep Adusumilli |
7036 |
Corona Loss Measurements in corona cage on UHV Bundle conductors |
Gunasekaran B,Yellaiah Anumulla |
7125 |
Tracking and Erosion Resistance of Nano-Filled Silicone Rubber for use in High Voltage Outdoor Insulators |
Venkatesulu B,Joy Thomas M |